GENEActiv Sleep
GENEActiv Sleep are made-to-order; please contact us for further details.
Please note: if direct skin temperature recordings are not vital within your study we recommend GENEActiv Original.
GENEActiv Sleep is a simple, reliable and cost-effective wrist-worn behavioural device used to research sleep interdependencies with health and lifestyle factors, improving sleep diagnosis. Specified for the monitoring of circadian rhythm, this variant allows the direct and continuous recording of skin temperature at any body location.
- Stainless steel temperature plate
- Splash proof
- Open source data format
As well as standard sleep actigraphy outputs, the raw data format allows many further analysis possibilities, for example:
- Full lifestyle & sleep assessment
- Position & tremor analysis
- Frequency domain analytics





-
Specification
Please note: specification is identical to that for the GENEActiv Original, with the exception of those items highlighted in orange below.
Physical Parameters Size 43mm x 40mm x 13mm Weight 16g (without strap) Main Housing Material PC/ABS (medical device grade) Light Guide Material PC (medical device grade) Data Contact Material Gold-plated Fixings 20mm heavy duty spring bar Strap PU resin Battery Type Rechargeable lithium polymer Environmental Protection Moisture Ingress Splashproof Material Ingress Dust tight (IP67) Operating Temperature 5 – 40 deg C Mechanical Impact 0.5m drop resistant Measurement Capabilities Memory 0.5Gb non-volatile Logging Frequencies Selectable 10-100Hz (10Hz) Maximum Logging Periods 45 days @ 10Hz; 7 days @ 100Hz Internal Clock Type Quartz Real Time Clock Frequency 32.7768kHz Accuracy +/- 20ppm (+/- 1.7s per day) Acceleration Measurements Sensor Type MEMS Range +/- 8g Resolution 12 bit (3.9 mg) Light Measurements Sensor Type Silicon photodiode Wavelength 400 to 1100 nm Range 0 – 3000 Lux typical Resolution 5 Lux typical Accuracy +/- 10% @ 1000 Lux calibration Event Logger Sensor Type Mechanical membrane switch Temperature Measurements Sensor Type Linear active thermister Range 0 to 60 deg C Resolution 0.25 deg C Accuracy +/- 1 deg C Measurement Frequency Every 30s minimum USB Connection Device USB 2.0 Full Speed Charge Cradle Format 4 unit cradle USB 2.0 High Speed Charge Time 90% @ 2 hours; 100% @ 3 hours Data Download Time Maximum 15 minutes for 4 concurrent units -
RegulatoryThis device complies with part 15 of the FCC Rules.This product is compliant with the Directive 2004/108/EC; tested to BS EN 61000-6-1 :2007 and BS EN 61000-6-3 :2007.